  • 1-1(1747200462971).jpg

DHC-1000 High Current Tester


Category:

Discrete Device Test System DTS-1000 Series


Product Description


1、Describe

The host is connected to the DTS-1000 to test various items of semiconductor transistors, FETs, and thyristors in the high current field, with a maximum test current of up to 200A.

 

2、Connection

 

3、Specification

Voltage/Current

IC : 00.0~200A

IB : 0.00m~50.0A

VCE : 0.00~30.0V

VGS : 0.00~30.0V

Test Devices

Transistors, Diode, MOS-FET, J-FET

System Station

Max Two Station

Relay action time

On Time 35ms Off Time 20ms But large current project test, don't do it.

Size

DHC-1000 500(W)×670(D)×250(H)mm CHD-1000 175(W)×355(D)×200(H)mm

Input Power Voltage

AC110V and AC220V Switch each other 50Hz/60Hz

Power consumption

500VA

Use conditions: Temperature:25℃±5℃. Humidity:Below 60%

 

4、4.Test item List (Measurement Range &Accuracy)

● Transistor

Test Item

Item Name

Measurement Range& Accuracy

Forcing Range& Accuracy

Forward
Voltage

HVFBE
HVFEC

000.0m ~ 30.00V ±(1%+2digit)
000.0m ~ 30.00V ±(1%+2digit)

IB: 0.00m ~ 50.0A   ±(1%+2digit)
IC: 00.0   ~ 200 A   ±(1%+2digit)

Saturation
Voltage

HVCESAT
HVBESAT

000.0m ~ 30.00V ±(1%+2digit)

IC: 00.0   ~ 200 A   ±(1%+2digit)
IB: 0.00m ~ 50.0A   ±(1%+2digit)

Base
Turn on

HBTON

000.0m ~ 30.00V ±(1%+2digit)

VCE: 0.00 ~ 30.0V ±(1%+2digit)
IC: 00.0   ~ 200 A   ±(1%+2digit)

DC Gain

HIB
HHFE *1

0.00m ~ 50.0A ±(1%+2digit)

VCE: 0.00 ~ 30.0V ±(1%+2digit)
IC: 00.0   ~ 200 A   ±(1%+2digit)

1: Use HFE=IC/ICB to calculation result.

 

● FET

Test Item

Item Name

Measurement Range& Accuracy

Forcing Range& Accuracy

Forward
Voltage

HVFGS
HVFSD

000.0m ~ 30.00V ±(1%+2digit)
000.0m ~ 30.00V ±(1%+2digit)

IG: 0.00m ~ 50.0A   ±(1%+2digit)
ID: 00.0   ~ 200 A   ±(1%+2digit)

Pinch-off
Voltage

HVP

000.0m ~ 30.00V ±(1%+2digit)

VDS: 0.00 ~ 30.0V ±(1%+2digit)
ID: 00.0   ~ 200 A   ±(1%+2digit)

Drain-Source
Voltage

HVDSON

000.0m ~ 30.00V ±(1%+2digit)

IC: 00.0   ~ 200 A   ±(1%+2digit)
VGS: 0.00 ~ 30.0V ±(1%+2digit)

On
Resistance

HRDON

0.000 ~ 999.9kR

Drain Current

HHIDSS

00.00 ~ 200.0A ±(1%+2digit)

VDS: 0.00 ~ 30.0V ±(1%+2digit)

HIDON

00.00 ~ 200.0A ±(1%+2digit)

VDS: 0.00 ~ 30.0V ±(1%+2digit)
VGS: 0.00 ~ 30.0V ±(1%+2digit)

YFS

HdVGS
HGMP *2

000.0m ~ 999.9mV ±(2%+2digit)

VDS: 0.00 ~ 30.0V ±(1%+2digit)
ID: 00.0   ~ 200 A ±(1%+2digit)

2:Use HGMP=0.1*ID/HdVGS Through this equation work out the results

 

● SCR

Test Item

Item Name

Measurement Range& Accuracy

Forcing Range & Accuracy

Forward
Voltage

HVGFM

000.0m ~ 30.00V    ±(1%+2digit)

IG: 0.00m ~ 50.0A  ±(1%+2digit)

On Voltage

HVTM

000.0m ~ 30.00V    ±(1%+2digit)

IT: 00.0  ~ 200 A  ±(1%+2digit)
IG: 0.00m ~ 50.0A  ±(1%+2digit)

Previous Page

Thyristor

Next Page

Contact Us

%{tishi_zhanwei}%