Discrete Device Test System DTS-1000 Series


Product Description


1、Features

Added the test function of HD-1240 (LOW RDON) and improved the test stability by dozens of times.

 

2、Specification

LRDON test range: 99.99mR-999.9uR

Input protection voltage: Max ±120V

Input voltage (CV): Max ±13V

Input voltage (EV): Max ±12V

Differential detection voltage: Max ±999.9mV

Differential detection voltage range: 3 Ranges

0.000mV-9.999mV Error: ±0.5% 1 0igit

00.00mV-99.99mV Error: ±0.5%2digit

000.0mV-999.9mV Error: ±0.5%2digit

 

3、Test Data

The difference between the test RDON and LRDON is shown in the following table:

Comparison of test data between RDON and LRDON (data measured using 1mR precision resistor)

Existing RDON test data

LRDON test data

1.02mR

1.00mR

0.98mR

1.00mR

1.01mR

1.00mR

0.99mR

1.00mR

This test data shows that the test data using HD-1240 (LRDON) values ​​are very stable.

 

4、RDON and LRDON test selection rules: (Important)

ID current × target RDON value < 10mV

Must use LRDON project test

ID current × target RDON value < 100mV

Recommended to use LRDON project test

ID current × target RDON value ≧ 100mV

Select RDON project test

 

5、Transformation method

You can use HD-1200 to replace the test station with HD-1240 for transformation. If you already have HD-1200, you can send the HD-1200 test station to our company for upgrade.

 